1.The flame keep above the glass products,radiant tube radiation heating.
2.Burning part adopts subsection control,automatic temperature adjustment,the user can set different temperature of the each heating section,based on the different products,from this achieve the desired temperature.
3.The hot air circulation fan, double stainless steel container,the end of the slow cooling zone has the waste heat recovery system.
4.Uniform temperature,All Stainless Steel combustion chamber,long serving life.
5.Full automatic control, more precise temperature-control, automatic control temperature difference ± 1 ℃, lower energy consumption.
6.Accepts customized according to customer requirements.We can Shorten or lengthen the furnace based on the output of the host,that ensure the customer use it reasonably.
No. |
Item
|
Unit
|
Main technical parameters of Model WLQ-RTS
|
|||||||||||
WLQ
-RTS
600
|
WLQ
-RTS
900
|
WLQ
-RTS
1200
|
WLQ
-RTS
1500
|
WLQ
-RTS
1800
|
WLQ
-RTS
2100
|
WLQ
-RTS
2400
|
WLQ
-RTS
2700
|
WLQ
-RTS
3000
|
WLQ
-RTS
3300
|
WLQ
-RTS
3600
|
WLQ
-RTS
4200
|
|||
1
|
Width of
Mesh belt
B(mm)
|
mm
|
600
|
900
|
1200
|
1500
|
1800
|
2100
|
2400
|
2700
|
3000
|
3300
|
3600
|
4200
|
2
|
Lever Height
of Mesh belt
|
mm
|
900-1000(or Customized)
|
|||||||||||
3
|
Mesh belt
Speed
|
mm/
min
|
10-500
|
|||||||||||
4
|
Allowable
Maximum Temperature
|
℃
|
630
|
|||||||||||
5
|
Furnace Hight
|
mm
|
350/400
|
|||||||||||
6
|
Furnace Profile
Temperature Difference
|
℃
|
±2
|
|||||||||||
7
|
Mesh Belt
Max Capacity
|
kg/
m2
|
90
|
|||||||||||
8
|
Thickness of
Stainless Steel
Container
|
mm
|
3
|
|||||||||||
9
|
Gear Motor Power
|
kw
|
1.1-3
|
|||||||||||
10
|
Circulation Fan
Motor Power
|
kw
|
1.1-2.2
|
|||||||||||
11
|
Motor Power of
Waste Heat
Recovery Fan
|
kw
|
0.75-1.5
|
|||||||||||
12
|
Fuel Type
|
natural gas、liquefied petroleum gas、Light diesel oil
|
||||||||||||
13
|
Combustion Machine
Origin
|
Italy or Germany
|
||||||||||||
14
|
gas control
|
electromagnetic control or Germany proportional control
|
||||||||||||
15
|
Temperature Control
Methods
|
full-automatic independent control
|
||||||||||||
16
|
Equipment
Full Length
|
mm
|
25000-28000
|
|||||||||||
17
|
Width of
High-temperature
section
|
mm
|
B+1100
|
|||||||||||
18
|
Width of
Heat Preservation
Zone
|
mm
|
B+600
|